1) CONSULT-II VERSION INFORMATION
2) CONSULT Error Code 106 when following instructions in the Nissan Bulletin # NTB05-115
3) How do I update CONSULT-II?
4) Issue with updating the Diagnostic Software Card?
5) How do I know if my computer has an Ethernet Card?.
6) ASIST is not able to communicate with CONSULT-II.
7) ECM/TCM data transfer OK, but software cards do not update.
8) Does CONSULT-II use a special Cable?
9) What is a Hub?
10) What do I do to repair my CONSULT-II?
11) When ECM/TCM data is selected, a Run-Time Error appears
12) ASIST is having a problem uploading reprogramming data into CONSULT-II.
13) CONSULT-II does not start up.
14) My CONSULT-II has an error message -START.INI
15) How do I get additional CONSULT-II cards?
16) ECM data is not displayed on the card after completing ECM download from ASIST, what is wrong?.
17) After turning on CONSULT-II it only beeps and blinks with no display, what is wrong?
18) What is the difference between the standard reprogramming card and the campaign card?
19) CONSULT-II MSSTDFMT.DLL Error - Use only if directed by the ASIST Support Team.
20) CONSULT-II MSFLXGRD.OCX Error - Use only if directed by the ASIST Support Team.
 

CONSULT-II VERSION INFORMATION
 
 • Diagnostic Software: UED06E-1

• NATS Software: AEN06B

• ECU Reprogramming: AER07A (8MB card only)

• ECU Reprogramming: AER07A (16MB card only)

top of page
CONSULT Error Code 106 when following instructions in the Nissan Bulletin # NTB05-115
 
 Receiving CONSULT error 106 when transferring data to my CONSULT-II unit when following instructions in the NTB05-115 bulletin.

Please follow these instructions to reinstall your software onto your ECU Reprogramming card:

1) Turn your CONSULT unit off

2) Go to the 'CONSULT Utilities' Main Menu screen from ASIST.

3) Select 'Software Updates'.

4) Follow ASIST CONSULT on- screen instructions.

5) Select 'ECU Reprogramming' and follow on-screen instructions.

6) After you have updated the ECU Reprogramming card, please go back to bulletin NTB05-115 and again follow the instructions to add the ECM data.

If you are still having problems, please contact the support line at 1-800-662-3282, Option 4.

top of page
How do I update CONSULT-II?
 
 The first step is to review the CONSULT-II Software Cards bulletin covering the procedures for setting up your computer's Ethernet card and CONSULT-II. (Nissan: NTB00-022b or Infiniti: ITB00-017b)
top of page
Issue with updating the Diagnostic Software Card?
 
 If the diagnostic card does not update properly, retry the update process using ASIST. The Diagnostic software updated is a two step update process. Step 1) Software refresh. Step 2) Software update. Incident Symptom: When the card is updated and CONSULT-II is powered on, it beeps and blinks repeatedly and does not boot up normally. Solution: A) Place the CONSULT-II back into Trasfer Files via LAN mode (if the C-II is still beeping and blinking, place your finger on the screen to get back to resident mode). B) Update the card a second time.
top of page
How do I know if my computer has an Ethernet Card?.
 
 The CONSULT-II Software Cards bulletin covers the procedures for setting up your computer's Ethernet card and CONSULT-II. (Nissan: NTB00- 022b or Infiniti: ITB00-017b)
top of page
ASIST is not able to communicate with CONSULT-II.
 
 The first step is to review the CONSULT-II Software Cards bulletin covering the procedures for setting up your computer's Ethernet card and CONSULT-II. (Nissan: NTB00-022b or Infiniti: ITB00-017b)
 Download: Test Download CONSULT
top of page
ECM/TCM data transfer OK, but software cards do not update.
 
 If you recently converted to ASIST and have two network cards, you have two choices: Option 1) Disable the internet connection temporarily when you need to perform a software update. This is done in the Control Panel/Network connections. "Right-click" on the Internet Local Area Connection and select "disable". After the software update is complete, "enable" the internet connection using the same steps. Option 2) Swap the network TCP/IP and Subnet mask settings and cables for each of the network cards. The LAN/Internet ethernet port will be used for CONSULT-II communication and the current CONSULT-II port will be used for the LAN/Internet connection. Write down all the TCP/IP numbers before making this change (IP address, Subnet mask, default gateway, Perferred DNS server and Alternate DNS server) Be sure to swap the cables in the back of the PC (Unplug the internet cable and CONSULT cable, and switch the port that they plug into).
top of page
Does CONSULT-II use a special Cable?
 
 It depends on how CONSULT-II is attached to the Computer. CONSULT-II comes with a special "CrossOver" Cable which attaches directly from the computer to the CONSULT-II. If you use a Hub then a standard "straight" Ethernet cable is needed to attach from the Hub to the CONSULT- II.
top of page
What is a Hub?
 
 For computers which are attached to a LAN or directly to a DSL/Cable connection, a Router Hub or Hub is ideal for attaching CONSULT-II into the network. One note is to be sure to use a standard Ethernet cable when attaching to a Hub. (Currently CONSULT-II uses a CrossOver Ethernet cable when attached directly into your computer.)
top of page
10 What do I do to repair my CONSULT-II?
 
 When your CONSULT-II needs to be repaired, review bulleting NTB00-057a for details.
 Download: Bulletin
top of page
11 When ECM/TCM data is selected, a Run-Time Error appears
 
 While trying to run ECM/TCM data, I'm receiving a 'Run-time error'. Please follow these instructions:

1) Click on the attached download file 'VB Runtime Install',

2) Click 'Open',

3) Click 'Yes' to install....

4) Restart computer.

Retry running ECM/TCM data.

 Download: VB Runtime Install
top of page
12 ASIST is having a problem uploading reprogramming data into CONSULT-II.
 
 The first step is to review the ECM Reprogramming bulletin covering the procedures for setting up your computer's Ethernet card and CONSULT-II. (Nissan: NTB00-006b or Infiniti: ITB00-005b)
top of page
13 CONSULT-II does not start up.
 
 The following installation message, or when a user clicks ECM/TCM data button under CONSULT Utilities means that their Internet Explorer version needs to be upgraded before the CONSULT ECU reprogramming function can work.
top of page
14 My CONSULT-II has an error message -START.INI
 
 This is generally an indication that the CONSULT-II card is corrupted.
top of page
15 How do I get additional CONSULT-II cards?
 
 Contact the SPX order desk. The tools catelog found in ASIST will provide details.
top of page
16 ECM data is not displayed on the card after completing ECM download from ASIST, what is wrong?.
 
 This is generally an indication that a card update procedure was performed. Try running the reprogramming procedure again and verify that - ECM/TCM DATA is selected.
top of page
17 After turning on CONSULT-II it only beeps and blinks with no display, what is wrong?
 
 This is generally an indication that CONSULT-II data may be damaged or missing. Try updating the card using ASIST or perform a card to card copy if a second card is available.
top of page
18 What is the difference between the standard reprogramming card and the campaign card?
 
 The campaign card only affects Nissan. The campaign card is a 16mb card which has been preloaded with the needed data to support campaign # . The standard card is a 8mb card used for all other reprogramming tasks. Individual campaign data are available in ASIST and may be used to suppliment the campaign card.
top of page
19 CONSULT-II MSSTDFMT.DLL Error - Use only if directed by the ASIST Support Team.
 
 This is only to be used under the direction of the ASIST support team. Step 1: Please download the attached msstdfmt.dll to your c:\windows\system32 (or c:\winnt\system32) folder Step 2: Click windows task bar 'Start' button and select 'Run...' and type the command

regsvr32.exe c:\windows\system32\msstdfmt.dll in the white space and click 'OK'

 Download: VB MSSTDFMT.DLL
top of page
20 CONSULT-II MSFLXGRD.OCX Error - Use only if directed by the ASIST Support Team.
 
 This is only to be used under the direction of the ASIST support team.

Windows XP Users:

1: Please download msflxgrd.ocx to your c:\windows\system32 folder

2: Click windows task bar 'Start' button and select 'Run...' and type the command "regsvr32.exe c:\windows\system32 \MSFLXGRD.OCX" in the white space and click 'OK'

Windows 2000 Users:

1: Please download MSFLXGRD.OCX to your c:\winnt\system32 folder

2: Click windows task bar 'Start' button and select 'Run...' and type the command "regsvr32.exe c:\winnt\system32 \MSFLXGRD.OCX" in the white space and click 'OK'

Relaunch ECU Reprog. Data to perform updates.

 Download: MSFLXGRD.OCX
top of page